Daniel JuniorSonic 3412 Two-Path Gas Ultrasonic Flow Meter

Daniel

Daniel JuniorSonic 3412 Two-Path Gas Ultrasonic Flow Meter

Daniel

Ideal for allocation and check metering, the fully-redundant Daniel™ JuniorSonic™ 3412 Two-Path Gas Ultrasonic Flow Meter combines a dual-bounce path design with powerful 3410 Series Electronics to ensure a superior non-fiscal measurement solution. This cost-effective meter is wet gas tolerant and features rugged Daniel T-21 Transducers that are engineered for wet, rich and/or dirty gas applications for reliable, long-term performance. Innovative MeterLink™ Software ensures operators have easy access to the diagnostics generated by the meter for real-time detection of flow disturbances.

Specifications

Line Sizes
DN100 to DN900 (4-in to 36-in)
Fluid Type
Gas
Accuracy
±0.2% of reading with calibration (±1.5% of actual flow volume without calibration)
Repeatability
±0.1% of reading for 5 to 100 fps (1.5 to 30.5 m/s)
Velocity
Rated up to 100 fps (30 m/s) with over-range performance exceeding 125 fps (38 m/s) on some sizes
Operating Temperature Range
  • T-21 Transducers: -20°C to +100°C (-4°F to +212°F)
  • Electronics: -40°C to +60°C (-40°F to +140°F
Operating Pressure Range
1,034 to 27,579 kPag (150 to 4,000 psig)
Materials
Carbon steel and stainless steel

Features

  • With the volatile prices of natural gas and petroleum products, a seemingly small measurement error can have a significantimpact on your operation’s bottom line.

    Emerson’s Measurement Uncertainty Analysis service reduces your risk of losing the value of any product volumes that cannot be confirmed. Our certified measurement technicians will visit your site, survey and test equipment and review design specifications. The data we gather will be used to quantify the level of uncertainty in your metering installation and enable us to recommend solutions that reduce the uncertainty level in custody transfer and fiscal flow measurement.

    The advantages include:

    • Substantial savings
    • Improved accuracy
    • Greater loss control
    • Visibility into elements or practices causing deviation
  • Virtually eliminate incremental pressure drop and reduce energy costs with the meter’s full-bore design
  • Improve maintenance practices and lower costs with no internal moving parts
  • Detect flow disturbances in real time with ultra-fast Daniel 3410 Series Electronics to minimize uncertainty
  • Monitor flow analysis and receive an intuitive view of meter health with integrated Daniel MeterLink Software
  • Enhance performance in harsh conditions long term with rugged Daniel T-21 Transducers
  • Field-replaceable transformer module simplifies maintenance and maximizes uptime
  • Reduce manual errors with automatic calculations of AGA 8 Compressibility and AGA 10 Speed of Sound
  • Increase I/O with new Type 4 CPU Module with up to six frequency or digital outputs