Every Micro Motion Coriolis meter measures mass flow, density, and temperature, but each family is optimized for different process requirements. Compare solutions by application, operating conditions, performance needs, materials, and line sizes to quickly identify the best meter for your measurement challenge.
Ultimate measurement confidence for the most demanding applications
- Why choose it: Delivers the highest measurement performance, broadest operating envelope, and strongest resilience to challenging process conditions
- Typical applications: Custody transfer, critical process control, chemical processing, refining, LNG, CCUS, two-phase flow
- Materials: 316L Stainless Steel, 304L Stainless Steel, Nickel Alloy C22
- Line sizes: 1/12" to 14“
- Choose another sensor if: Your application does not require maximum performance and you are optimizing for footprint or installed cost
Versatile measurement for everyday process applications across industries
- Why choose it: Compact, versatile design balancing performance, footprint, and ease of installation
- Typical applications: Food and beverage, life sciences, batching, filling, general process measurement, OEM skids
- Materials: 316L Stainless Steel, Electropolished option
- Line sizes: 1/4" to 3"
- Choose another sensor if: You need maximum accuracy, demanding process control, or custody transfer performance
Fast, high-accuracy measurement for process control
- Why choose it: Optimized for rapid response and process control
- Typical applications: Dosing, blending, reactor feeds, batching
- Materials: 316L Stainless Steel, Nickel Alloy C22
- Line sizes: 1/4" to 4"
- Choose another sensor if: You need maximum performance for custody transfer, difficult gases, slurries, or two-phase flow
Compare Coriolis Meters
Quickly evaluate all Micro Motion Coriolis sensor families side by side. Compare application fit, materials, performance capabilities, and certifications to identify the right solution for your process requirements and operating conditions.
Demanding and critical measurement across the broadest range of applications | Ultimate performance | Custody transfer, two-phase flow, LNG, CCUS | Custody Transfer, SIL, Hazardous Area, Marine, EHEDG, 3-A | |
Versatile flow and density measurement for everyday process applications | Application versatility | Batching, filling, OEM equipment, food and beverage | Hazardous Area, Marine, 3-A, EHEDG, ASME BPE | |
High-accuracy process control and rapidly changing process conditions | Fast response accuracy | Dosing, blending, reactor feeds, batch control | Hazardous Area, SIL, Marine | |
Hygienic food, beverage, and life process control | Hygienic design | Dairy, food and beverage, life sciences, batching and filling | 3-A, EHEDG, ASME BPE, Hazardous Area | |
Hygienic processes requiring a straight, unobstructed flow path | Single straight-tube design | Biopharmaceuticals, ultra-pure fluids, product recovery, viscous fluids | 3-A, EHEDG, ASME BPE, Hazardous Area | |
Highly corrosive liquid applications | Pure tantalum wetted parts | Acids, corrosive chemicals, specialty chemicals | Hazardous Area, SIL | |
Ultra-high-pressure hydrogen, CCUS, and chemical injection | Ultra-high-pressure capability | Hydrogen dispensing, chemical injection, CCUS, high-pressure processes | OIML R139-1, Hazardous Area | |
Cryogenic LNG measurement and custody transfer | Dedicated cryogenic design | LNG dispensing, loading, unloading, custody transfer | MID, OIML, Weights & Measures, Hazardous Area | |
Compressed natural gas fueling and dispensing | Dedicated CNG measurement | Fueling stations, fleet fueling, heavy-duty vehicle dispensers | AGA 11, Weights & Measures, Hazardous Area |

How Coriolis Flow Meters Measure Mass Flow with Precision
Micro Motion Coriolis meters use vibrating tubes to measure mass flow directly. As fluid moves through the sensor, it creates a measurable twist in the vibration. This phase shift is converted into a highly accurate mass flow measurement delivering reliable, real‑time insight without compensation. In addition, the Coriolis meter measures liquid density and process fluid temperature.
Products
Select the Right Coriolis Transmitter for Your Application
Critical measurement, custody transfer, advanced process control | Maximum capability | Complete measurement visibility and application flexibility | |
Process control, OEM skids, specialty measurement | Configurable diagnostics | Greater process insight without added complexity | |
Brownfield upgrades, existing 2-wire installations | Loop-powered design | Reliable measurement with minimal installation effort | |
Filling, dosing, compact OEM skids | Compact connectivity | Modern communications in a small footprint | |
Batching, blending, terminal operations | Integrated control platform | Measurement and control in one system | |
Custody transfer, specialty measurement applications | Advanced application platform | Purpose-built calculations and control capabilities | |
Density, concentration, process calculations | Density expertise | Advanced density-based process optimization | |
Basic flow monitoring applications | Fast fill | Cost-effective flow measurement | |
Flow, density, concentration measurement | Proven multivariable measurement | Broad application flexibility | |
Standard single-variable flow measurement | Essential flow measurement | Reliable flow measurement with simple operation |
SERVICES & CONSULTING
Get Expert Support Throughout the Meter Lifecycle
From sizing and selection to commissioning, and ongoing support, Emerson provides the tools and expertise needed to confidently deploy and maintain your Coriolis flow measurement solution.
Frequently Asked Questions
Explore these frequently asked questions to learn how Micro Motion Coriolis flow meters deliver precise, reliable measurement across a wide range of industrial applications.
Micro Motion Coriolis meters directly measure mass flow, density, and temperature, so they can continue measuring the actual fluid mixture in the tubes during entrained gas or two-phase conditions, but density will reflect the lower-density mixture and the best application fit depends on gas regime, sensor frequency, transmitter configuration, and operating stability; for difficult two-phase applications, Micro Motion ELITE meters are identified as the strongest fit, while G-Series is not recommended for entrained-air two-phase applications because its high operating frequency can increase measurement error, and traditional technologies such as turbine, PD, thermal mass, and volumetric meters may be more affected by moving-part wear, volumetric property changes, flow conditioning, or inability to directly measure mass.
For custody transfer or proving of liquid hydrocarbons, use a Micro Motion ELITE Coriolis meter and configure the transmitter for fast response where proving performance is critical, because API MPMS Chapter 5.6, Measurement of Liquid Hydrocarbons by Coriolis Meters, defines Coriolis pulse scaling factor behavior for proving and covers crude oil, hydrocarbon products, and dense-phase fluids such as LPG, NGL, and LNG; internal proving guidance recommends fastest available response mode, 0.0 seconds flow damping, 0.16 seconds density damping, and ensuring pulse frequency at maximum flow does not exceed the prover pulse counter capacity.
Micro Motion ELITE Coriolis meters are appropriate for CCUS and CO₂ applications because Coriolis technology directly measures mass flow independent of whether CO₂ is gas, liquid, dense phase, or supercritical, and internal CCUS guidance cites ±0.25% mass flow accuracy uncertainty for CO₂ measurement while noting that pressure may need to be measured or known in high-pressure applications to compensate for Coriolis tube stiffness effects; for engineered high-pressure CO₂ applications, Micro Motion High Pressure ELITE models are documented up to 4,641 psig (320 bar), including CMF300M to 250 bar, CMF400P to 260 bar, and CMF400H to 320 bar depending on configuration and regulatory constraints.
For hygienic or sanitary process applications, Micro Motion Hygienic G-Series is suited to compact OEM skids, Life Sciences, and Food & Beverage duties requiring 3-A authorization, EHEDG certification, ASME BPE design compliance, CIP/SIP compatibility, 316/316L or 317/317L wetted parts, and 30 Ra (0.76 μm) or 15 Ra (0.38 μm) electropolished wetted surfaces, while H-Series is a better fit when the application requires compact hygienic design plus improved two-phase or entrained-air capability, and ELITE is the better fit for the broadest range of demanding hygienic, cryogenic, high-pressure, high-temperature, slurry, or multiphase conditions.
Micro Motion Smart Meter Verification can be used to check Coriolis meter health in situ without interrupting the process, and a petrochemical custody-transfer case study describes a site with 100 Micro Motion Coriolis meters using 5700 Transmitters to move away from twice-yearly manual verification that required removing meters from service. Smart Meter Verification is a traceable, on-demand or scheduled verification method that can provide confidence in meter functionality in less than 90 seconds; whether it replaces calibration or only supports longer calibration intervals depends on site quality procedures, regulatory requirements, and accepted documentation for the application.