FLEXIM · MICRO MOTION · ROSEMOUNT · ROXAR

Which Flow Meter Is Right for Your Application?

Emerson makes eight flow measurement technologies, and your process can help you make a decision for what is best. See the comparisons below to help guide your decision.

Flow Technologies

Find Your Best Match

Explore Emerson’s comprehensive portfolio of flow measurement technologies designed to deliver reliable, accurate measurement across a wide range of fluids, applications and industries. Compare flow solutions to find the right technology for your process conditions, performance requirements and measurement goals.

AT A GLANCE

Compare All Eight Technologies

Review Emerson's Flow Technologies side-by-side to help you decide which technology is right for you.

Mass flow, volumetric flow, density, temperature

Liquids, gases, slurries

Process control, custody transfer, batching, blending, dosing

Hazardous Area (ATEX, IECEx, CSA), SIL2/SIL3, Custody Transfer (NTEP, MID, Measurement Canada, OIML), PED/CRN, Hygienic (3-A, EHEDG, ASME BPE)

Volume

Conductive liquids, typically ≥2 µS/cm, slurries

Water, chemicals, high solids content, corrosive media

Hazardous Area (ATEX, IECEx, CSA), PED/CRN, Hygienic (3-A)

Volume; mass with added P and T

Liquids, gases, steam

Steam, gas, plant utilities, custody transfer

Hazardous Area (ATEX, IECEx, CSA), SIL2/3, (OIML R137), PED/CRN, API 14.12

Volume; mass with compensation, static pressure, temperature

Liquids, gases, steam, slurries

Steam, gas, plant utilities, process control

AGA-3, ISO 5167, ASME MFC-14M

Volume

Liquids, gases

Custody transfer, allocation, check metering, leak detection

AGA 9, ISO 17089, OIML R137/R117, MID, Measurement Canada, API MPMS 5.8, PED, ATEX, IECEx, NACE

Volumetric flow, mass flow, concentration, density, interface detection

Liquids, gases, steam

No-shutdown measurements, challenging process conditions (high pressure, high temperature, corrosive media), large pipes, and temporary surveys, compressed air

Hazardous Area (ATEX, IECEx, FM, KOSHA, JPEx CML, China Ex, PESO, INMETRO, CAS), SIL2, DNV marine, MCERTS

Oil, water and gas rates

Unseparated well stream

Ownership allocation, reservoir management, flow assurance, production optimization, well testing operations

API MPMS 20.3

Water content in oil, sensitive to 50 ppm

Oil, water

Allocation, custody transfer, fiscal measurement, separator performance

API MPMS 10.10

Frequenly Asked Questions

Flow measurement is the quantification of how much liquid, gas, or steam moves through a pipe or process system. Accurate flow measurement is critical for maintaining process control, ensuring product quality, optimizing energy use, and meeting safety and regulatory requirements across industries such as oil and gas, chemical, water and wastewater, life sciences, power generation, metals and mining, marine, refining, and more.​

The right flow meter depends on several key factors, including fluid type, required accuracy, process conditions, and installation constraints.​

 

  • Coriolis flow meters are ideal for high-accuracy mass flow and custody transfer​
  • Magnetic flow meters perform best in conductive liquid applications such as water and slurry​
  • Differential pressure (DP) flow meters are widely used for steam, gas, and legacy installations​
  • Vortex flow meters are well suited for steam and clean gas measurement​
  • Ultrasonic flow meters offer non-intrusive or high-precision measurement for liquids gases, and steam

Evaluating these variables ensures the selected technology delivers reliable performance and long-term value.​

Each flow measurement technology uses a different principle to measure flow:​

  • Coriolis measures mass flow directly using tube vibration​
  • Magnetic measures volumetric flow based on fluid conductivity and electromagnetic induction​
  • Differential pressure (DP) calculates flow from pressure drop across a primary element​
  • Vortex detects vortices shed by the flowing fluid to determine velocity
  • Ultrasonic uses sound waves to measure flow velocity, either inline or non-intrusive​

These differences affect accuracy, maintenance requirements, pressure loss, and suitability for specific applications.​

Clamp-on ultrasonic flow meters are ideal when process interruption or pipe penetration should be avoided. They are particularly advantageous for large pipe sizes, high pressures, corrosive media, extreme temperatures, and hazardous areas, where inline installation can be complex or costly. Stationary non-intrusive meters provide a permanent measurement solution, while portable devices offer additional flexibility for temporary measurements.

Coriolis flow meters are typically preferred for high-accuracy applications because they measure mass flow directly and provide exceptional repeatability and stability. They are widely used in custody transfer scenarios where measurement precision directly impacts financial transactions and regulatory compliance. ​

Key process conditions that influence flow meter selection include:​

  • Fluid type (liquid, gas, steam, slurry, multiphase)​
  • Temperature and pressure range​
  • Flow rate and pipe size​
  • Fluid properties such as viscosity, density, and conductivity​
  • Presence of solids, bubbles, or contaminants​
  • Hazardous-area requirements
  • Installation conditions and available straight pipe run
  • Possibility of process shutdown and acceptable downtime

Understanding these conditions helps ensure accurate measurement and avoids performance issues over time.​

Modern flow measurement technologies are designed to perform reliably in demanding environments, including high pressure, extreme temperatures, corrosive media, and multiphase flow conditions. Advanced diagnostics, durable materials, and application-specific designs help maintain accuracy, reduce maintenance, and improve operational uptime.​

Accurate, real-time flow data enables operators to optimize control strategies, reduce waste, improve yield, and identify performance issues before they lead to downtime. When integrated with digital systems, flow measurement also supports predictive maintenance and data-driven decision-making across the plant.​

Selecting the optimal flow measurement technology can be complex, but the right tools and expertise make the process easier. Emerson provides application expertise, engineering tools, and digital selection platforms to help evaluate your requirements and recommend the best solution for your process.​

Products