Differential Pressure Level Measurement Across an Electrolyzer Stack

Measure across the electrolyzer stack for control & optimize the performance

Man near hydrogen power plant. Factory for production of h2 gas. Hydrogen energy. Power plant technologist with laptop. Man inspects hydrogen manufactory. Innovative electrical station on sunny day

Increase performance of electrolyzer stack

Differential pressure (DP) level measurement across an electrolyzer stack is essential for optimizing hydrogen production. Oxygen is produced at the cathode and hydrogen at the anode, requiring careful separation to prevent explosive oxyhydrogen formation. Reliable differential pressure measurement solutions include transmitters with remote seals and electronic remote sensors, ensuring accurate monitoring and control. Advanced sensor systems offer benefits such as easier installation, reduced inventory costs and flexible sensor placement. Different configurations and materials, such as gold-plated stainless steel for hydrogen resistance, enhance safety and performance in various operating conditions. The Rosemount™ 3051S ERS™ (Electronic Remote Sensor) Level Measurement System is ideal for this application.